Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 773
Filtrar
1.
bioRxiv ; 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38562769

RESUMO

Racial disparities in triple-negative breast cancer (TNBC) outcomes have been reported. However, the biological mechanisms underlying these disparities remain unclear. We integrated imaging mass cytometry and spatial transcriptomics, to characterize the tumor microenvironment (TME) of African American (AA) and European American (EA) patients with TNBC. The TME in AA patients was characterized by interactions between endothelial cells, macrophages, and mesenchymal-like cells, which were associated with poor patient survival. In contrast, the EA TNBC-associated niche is enriched in T-cells and neutrophils suggestive of an exhaustion and suppression of otherwise active T cell responses. Ligand-receptor and pathway analyses of race-associated niches found AA TNBC to be immune cold and hence immunotherapy resistant tumors, and EA TNBC as inflamed tumors that evolved a distinctive immunosuppressive mechanism. Our study revealed the presence of racially distinct tumor-promoting and immunosuppressive microenvironments in AA and EA patients with TNBC, which may explain the poor clinical outcomes.

2.
Bone ; : 117096, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38631596

RESUMO

High-resolution magnetic resonance imaging (HR-MRI) has been increasingly used to assess the trabecular bone structure. High susceptibility at the marrow/bone interface may significantly reduce the marrow's apparent transverse relaxation time (T2*), overestimating trabecular bone thickness. Ultrashort echo time MRI (UTE-MRI) can minimize the signal loss caused by susceptibility-induced T2* shortening. However, UTE-MRI is sensitive to chemical shift artifacts, which manifest as spatial blurring and ringing artifacts partially due to non-Cartesian sampling. In this study, we proposed UTE-MRI on the resonance frequency of fat to minimize marrow-related chemical shift artifacts and the overestimation of trabecular thickness. Cubes of trabecular bone from six donors (75 ±â€¯4 years old) were scanned using a 3 T clinical scanner on the resonance frequencies of fat and water, respectively, using 3D UTE sequences with five TEs (0.032, 1.1, 2.2, 3.3, and 4.4 ms) and a clinical 3D gradient echo (GRE) sequence at 0.2 × 0.2 × 0.4 mm3 voxel size. Trabecular bone thickness was measured in 30 regions of interest (ROIs) per sample. MRI results were compared with thicknesses obtained from micro-computed tomography (µCT) at 50 µm3 voxel size. Linear regression models were used to calculate the coefficient of determination between MRI- and µCT-based trabecular thickness. All MRI-based trabecular thicknesses showed significant correlations with µCT measurements. The correlations were higher (examined with paired Student's t-test, P < 0.01) for 3D UTE images performed on the fat frequency (R2 = 0.59-0.74, P < 0.01) than those on the water frequency (R2 = 0.18-0.52, P < 0.01) and clinical GRE images (R2 = 0.39-0.47, P < 0.01). Significantly reduced correlations were observed with longer TEs. This study highlighted the feasibility of UTE-MRI on the fat frequency for a more accurate assessment of trabecular bone thickness.

4.
J Bone Miner Res ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38591788

RESUMO

Ultrashort echo time (UTE) MRI can quantify the major proton pool densities in cortical bone, including total (TWPD), bound (BWPD), and pore water (PWPD) proton densities, as well as the macromolecular proton density (MMPD), associated with the collagen content, which is calculated using macromolecular fraction (MMF) from UTE magnetization transfer (UTE-MT) modeling. This study aimed to investigate the differences in water and collagen contents in tibial cortical bone, between female osteopenia (OPe) patients, osteoporosis (OPo) patients, and young participants (Young). Being postmenopausal and above 55 years old were the inclusion criteria for OPe and OPo groups. The tibial shaft of fourteen OPe (72.5 ± 6.8 years old), thirty-one OPo (72.0 ± 6.4 years old), and thirty-one young subjects (28.0 ± 6.1 years old) were scanned using a knee coil on a clinical 3 T scanner. Basic UTE, inversion recovery UTE, and UTE-MT sequences were performed. Investigated biomarkers were compared between groups using Kruskal-Wallis test. Spearman's correlation coefficients were calculated between the total hip dual-energy x-ray absorptiometry (DXA) T-score and UTE-MRI results. MMF, BWPD, and MMPD were significantly lower in OPo patients than in the young group. Whereas T1, TWPD, and PWPD were significantly higher in OPo patients. The largest OPo/Young average percentage differences were found in MMF (41.9%), PWPD (103.5%), and MMPD (64.0%). PWPD was significantly higher (50.7%), while BWPD was significantly lower (16.4%) in OPe than the Young group on average. MMF was found to be significantly lower (27%) in OPo patients compared with OPe group. T1, MMF, TWPD, PWPD, and MMPD values significantly correlated with the total hip DXA T-scores (provided by the patients and only available for OPe and OPo patients). DXA T-score showed the highest correlations with PWPD (R = 0.55) and MMF (R = 0.56) values. TWPD, PWPD, and MMF estimated using the UTE-MRI sequences were recommended to evaluate individuals with OPe and OPo.


Ultrashort echo time (UTE) is an MRI technique that can quantify the water and collagen content of cortical bone. Water in the bone can be found residing in pores (pore water) or bound to the bone matrix (bound water). We investigated the differences in water and collagen contents of tibial cortical bone, between female osteopenia patients, osteoporosis patients, and young participants. Bound water and collagen contents were significantly lower in osteoporosis patients than in the young group. Whereas total water and pore water contents were significantly higher in osteoporosis patients. Pore water was significantly higher, while bound water was significantly lower in osteopenia than in the Young group. Collagen content was found to be significantly lower in osteoporosis patients compared with the osteopenia group. The estimated water and collagen contents were significantly correlated with the total hip bone densitometry measures in the patients.

5.
Quant Imaging Med Surg ; 14(4): 3146-3156, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38617168

RESUMO

Background: Tendon and bone comprise a critical interrelating unit. Bone loss, including that seen with osteopenia (OPe) or osteoporosis (OPo), may be associated with a reduction in tendon quality, though this remains incompletely investigated. Clinical magnetic resonance imaging (MRI) sequences cannot directly detect signals from tendons because of the very short T2. Clinical MRI may detect high-graded abnormalities by changes in the adjacent structures like bone. However, ultrashort echo time MRI (UTE-MRI) can capture high signals from all tendons. To determine if the long T2 fraction, as measured by a dual-echo UTE-MRI sequence, is a sensitive quantitative technique to the age- and bone-loss-related changes of the lower leg tendons. Methods: This is a cross-sectional study conducted between January 2018 to February 2020 in the lower legs of 14 female patients with OPe [72±6 years old, body mass index (BMI) =25.8±6.2 kg/m2] and 31 female patients with OPo (73±6 years old, BMI=22.0±3.8 kg/m2), as well as 30 female subjects with normal bone (Normal, 35±18 years old, BMI =23.2±4.3 kg/m2), were imaged on a 3T clinical scanner using a dual-echo 3D Cones UTE sequence. We defined the apparent long T2 signal fraction (aFrac-LongT2) of tendons as the ratio between the signal at the second echo time (TE =2.2 ms) to the UTE signal. The average aFrac-LongT2 and the cross-sectional area were calculated for the anterior tibialis tendons (ATTs) and the posterior tibialis tendons (PTTs). The Kruskal-Wallis rank test was used to compare the differences in aFrac-LongT2 and the cross-sectional area of the tendons between the groups. Results: The aFrac-LongT2 of the ATTs and PTTs were significantly higher in the OPo group compared with the Normal group (22.2% and 34.8% in the ATT and PTT, respectively, P<0.01). The cross-sectional area in the ATTs was significantly higher for the OPo group than in the Normal group (Normal/OPo difference was 28.7, P<0.01). Such a difference for PTTs did not reach the significance level. Mean aFrac-LongT2 and cross-sectional area in the OPe group were higher than the Normal group and lower than the OPo group. However, the differences did not show statistical significance, likely due to the higher BMI in the OPe group. Conclusions: Dual-echo UTE-MRI is a rapid quantification technique, and aFrac-LongT2 values showed significant differences in tendons between Normal and OPo patients.

6.
J Imaging Inform Med ; 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38548992

RESUMO

We proposed an end-to-end deep learning convolutional neural network (DCNN) for region-of-interest based multi-parameter quantification (RMQ-Net) to accelerate quantitative ultrashort echo time (UTE) MRI of the knee joint with automatic multi-tissue segmentation and relaxometry mapping. The study involved UTE-based T1 (UTE-T1) and Adiabatic T1ρ (UTE-AdiabT1ρ) mapping of the knee joint of 65 human subjects, including 20 normal controls, 29 with doubtful-minimal osteoarthritis (OA), and 16 with moderate-severe OA. Comparison studies were performed on UTE-T1 and UTE-AdiabT1ρ measurements using 100%, 43%, 26%, and 18% UTE MRI data as the inputs and the effects on the prediction quality of the RMQ-Net. The RMQ-net was modified and retrained accordingly with different combinations of inputs. Both ROI-based and voxel-based Pearson correlation analyses were performed. High Pearson correlation coefficients were achieved between the RMQ-Net predicted UTE-T1 and UTE-AdiabT1ρ results and the ground truth for segmented cartilage with acceleration factors ranging from 2.3 to 5.7. With an acceleration factor of 5.7, the Pearson r-value achieved 0.908 (ROI-based) and 0.945 (voxel-based) for UTE-T1, and 0.733 (ROI-based) and 0.895 (voxel-based) for UTE-AdiabT1ρ, correspondingly. The results demonstrated that RMQ-net can significantly accelerate quantitative UTE imaging with automated segmentation of articular cartilage in the knee joint.

7.
Neuro Oncol ; 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459978

RESUMO

BACKGROUND: The American Radium Society (ARS) Central Nervous System (CNS) committee reviewed literature on epidermal growth factor receptor mutated (EGFRm) and ALK-fusion (ALK+) tyrosine kinase inhibitors (TKIs) for the treatment of brain metastases (BrMs) from non-small cell lung cancers (NSCLC) to generate appropriate use guidelines addressing use of TKIs in conjunction with or in lieu of radiotherapy (RT). METHODS: The panel developed three key questions to guide systematic review: can radiotherapy be deferred in patients receiving EGFR or ALK TKIs at 1) diagnosis or 2) recurrence? Should TKI be administered concurrently with RT (3)? Two literature searches were performed (May 2019 and December 2023). The panel developed 8 model cases and voted on treatment options using a 9-point scale, with 1-3, 4-6 and 7-9 corresponding to usually not appropriate, may be appropriate, and usually appropriate (respectively), per the UCLA/RAND Appropriateness Method. RESULTS: Consensus was achieved in only 4 treatment scenarios, all consistent with existing ARS-AUC guidelines for multiple BrM. The panel did not reach consensus that RT can be appropriately deferred in patients with BrM receiving CNS penetrant ALK or EGFR TKIs, though median scores indicated deferral may be appropriate under most circumstances. Whole brain RT with concurrent TKI generated broad disagreement except in cases with 2-4 BrM, where it was considered usually not appropriate. CONCLUSIONS: We identified no definitive studies dictating optimal sequencing of TKIs and RT for EGFRm and ALK+ BrM. Until such studies are completed, the committee hopes these cases guide decision-making in this complex clinical space.

8.
Arthritis Rheumatol ; 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38508862

RESUMO

OBJECTIVE: Oxylipins are bioactive lipids derived from polyunsaturated fatty acids (PUFAs) that modulate inflammation and may remain overexpressed in refractory synovitis. In plasma, they could also be biomarkers of synovial pathology. The aim of this study is to determine if synovial oxylipins in inflamed joints correlate with plasma oxylipins and with synovial histological patterns. METHODS: Patients with established rheumatoid or psoriatic arthritis with active disease despite treatment were recruited and paired ST and plasma were collected. Oxylipins were determined by liquid chromatography with tandem mass spectrometry and were classified into groups according to their PUFA precursor and enzyme. The expression of CD20, CD68, CD3 and CD138 was obtained to describe synovial histology. Cell specific expression of oxylipin-related genes were identified by examining available synovial scRNA-seq data. RESULTS: We included a total of 32 ST and 26 paired-plasma samples. A total of 71 oxylipins were identified in ST but only 24 were identified in plasma. Only levels of 9,10-diHOME and tetranor-PGFM had a significant positive correlation between plasma and ST. Several oxylipins and oxylipin-related genes were differentially expressed among synovial phenotypes. Specifically, several 5-LOX-derived oxylipins were statistically elevated in the lympho-myeloid phenotype, and associated with B cell expression in RA samples. CONCLUSION: The lack of correlation between ST and plasma oxylipins suggests that synovial tissue lipid profiling better characterizes active pathways in treated joints. Synovial 5-LOX-derived oxylipins were highly expressed in lympho-myeloid-enriched synovium. Combination therapy with 5-LOX inhibitors to improve refractory inflammation may be needed in patients with this histological group.

9.
Eur Radiol Exp ; 8(1): 21, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38316687

RESUMO

BACKGROUND: We investigated the relationship of two commonly used quantitative ultrasound (QUS) parameters, speed of sound (SoS) and attenuation coefficient (α), with water and macromolecular contents of bovine cortical bone strips as measured with ultrashort echo time (UTE) magnetic resonance imaging (MRI). METHODS: SoS and α were measured in 36 bovine cortical bone strips utilizing a single-element transducer with nominal 5 MHz center frequency based on the time of flight principles after accommodating for reflection losses. Specimens were then scanned using UTE MRI to measure total, bound, and pore water proton density (TWPD, BWPD, and PWPD) as well as macromolecular proton fraction and macromolecular transverse relaxation time (T2-MM). Specimens were also scanned using microcomputed tomography (µCT) at 9-µm isometric voxel size to measure bone mineral density (BMD), porosity, and pore size. The elastic modulus (E) of each specimen was measured using a 4-point bending test. RESULTS: α demonstrated significant positive Spearman correlations with E (R = 0.69) and BMD (R = 0.44) while showing significant negative correlations with porosity (R = -0.41), T2-MM (R = -0.47), TWPD (R = -0.68), BWPD (R = -0.67), and PWPD (R = -0.45). CONCLUSIONS: The negative correlation between α and T2-MM is likely indicating the relationship between QUS and collagen matrix organization. The higher correlations of α with BWPD than with PWPD may indicate that water organized in finer structure (bound to matrix) provides lower acoustic impedance than water in larger pores, which is yet to be investigated thoroughly. RELEVANCE STATEMENT: This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone, including the collagenous matrix and water. Investigating the full potential of QUS and its validation facilitates a more affordable and accessible tool for bone health monitoring in clinics. KEY POINTS: • Ultrasound attenuation demonstrated significant positive correlations with bone mechanics and mineral density. • Ultrasound attenuation demonstrated significant negative correlations with porosity and bone water contents. • This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone.


Assuntos
Osso e Ossos , Prótons , Animais , Bovinos , Microtomografia por Raio-X , Osso e Ossos/diagnóstico por imagem , Osso Cortical/diagnóstico por imagem , Água
10.
Semin Musculoskelet Radiol ; 28(1): 62-77, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38330971

RESUMO

Magnetic resonance imaging (MRI) is increasingly used to evaluate the microstructural and compositional properties of bone. MRI-based biomarkers can characterize all major compartments of bone: organic, water, fat, and mineral components. However, with a short apparent spin-spin relaxation time (T2*), bone is invisible to conventional MRI sequences that use long echo times. To address this shortcoming, ultrashort echo time MRI sequences have been developed to provide direct imaging of bone and establish a set of MRI-based biomarkers sensitive to the structural and compositional changes of bone. This review article describes the MRI-based bone biomarkers representing total water, pore water, bound water, fat fraction, macromolecular fraction in the organic matrix, and surrogates for mineral density. MRI-based morphological bone imaging techniques are also briefly described.


Assuntos
Osso e Ossos , Imageamento por Ressonância Magnética , Humanos , Osso e Ossos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Água/química , Minerais
11.
Quant Imaging Med Surg ; 14(2): 1673-1685, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415151

RESUMO

Background: Myelin water imaging (MWI) is a myelin-specific technique, which has great potential for the assessment of demyelination and remyelination. This study develops a new MWI method, which employs a short repetition time adiabatic inversion recovery (STAIR) technique in combination with a commonly used fast spin echo (FSE) sequence and provides quantification of myelin water (MW) fractions. Method: Whole-brain MWI was performed using the short repetition time adiabatic inversion recovery prepared-fast spin echo (STAIR-FSE) technique on eight healthy volunteers (mean age: 38±14 years, four-males) and seven patients with multiple sclerosis (MS) (mean age: 53.7±8.7 years, two-males) on a 3T clinical magnetic resonance imaging scanner. To facilitate the quantification of apparent myelin water fraction (aMWF), a proton density-weighted FSE was also used during the scans to allow total water imaging. The aMWF measurements of MS lesions and normal-appearing white matter (NAWM) regions in MS patients were compared with those measured in normal white matter (NWM) regions in healthy volunteers. Both the analysis of variance (ANOVA) test and paired comparison were performed for the comparison. Results: The MW in the whole-brain was selectively imaged and quantified using the STAIR-FSE technique in all participants. MS lesions showed much lower signal intensities than NAWM in the STAIR-FSE images. ANOVA analysis revealed a significant difference in the aMWF measurements between the three groups. Moreover, the aMWF measurements in MS lesions were significantly lower than those in both NWM of healthy volunteers and NAWM of MS patients. Lower aMWF measurements in NAWM were also found in comparison with those in NWM. Conclusions: The STAIR-FSE technique is capable of measuring aMWF values for the indirect detection of myelin loss in MS, thus facilitating clinical translation of whole brain MWI and quantification, which show great potential for the detection and evaluation of changes in myelin in the brain of patients with MS for future larger cohort studies.

13.
Bioengineering (Basel) ; 11(1)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38247943

RESUMO

Introduction: The objective of this study was to assess the bi-exponential relaxation times and fractions of the short and long components of the human patellar tendon ex vivo using three-dimensional ultrashort echo time T1ρ (3D UTE-T1ρ) imaging. Materials and Methods: Five cadaveric human knee specimens were scanned using a 3D UTE-T1ρ imaging sequence on a 3T MR scanner. A series of 3D UTE-T1ρ images were acquired and fitted using single-component and bi-component models. Single-component exponential fitting was performed to measure the UTE-T1ρ value of the patellar tendon. Bi-component analysis was performed to measure the short and long UTE-T1ρ values and fractions. Results: The single-component analysis showed a mean single-component UTE-T1ρ value of 8.4 ± 1.7 ms for the five knee patellar tendon samples. Improved fitting was achieved with bi-component analysis, which showed a mean short UTE-T1ρ value of 5.5 ± 0.8 ms with a fraction of 77.6 ± 4.8%, and a mean long UTE-T1ρ value of 27.4 ± 3.8 ms with a fraction of 22.4 ± 4.8%. Conclusion: The 3D UTE-T1ρ sequence can detect the single- and bi-exponential decay in the patellar tendon. Bi-component fitting was superior to single-component fitting.

14.
Int J Radiat Oncol Biol Phys ; 118(2): 565-573, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37660738

RESUMO

PURPOSE: Dose heterogeneity within a tumor target is likely responsible for the biologic effects and local tumor control from spatially fractionated radiation therapy (SFRT). This study used a commercially available GRID-pattern dose mudulated nonuniform radiation therapy (GRID) collimator to assess the interplan variability of heterogeneity dose metrics in patients with various bulky tumor sizes and depths. METHODS AND MATERIALS: The 3-dimensional heterogeneity metrics of 14 bulky tumors, ranging from 155 to 2161 cm3 in volume, 6 to 23 cm in equivalent diameter, and 3 to 13 cm in depth, and treated with GRID collimator-based SFRT were studied. A prescription dose of 15 Gy was given at the tumor center with 6 MV photons. The dose-volume histogram indices, dose heterogeneity parameters, and peak/valley dose ratios were derived; the equivalent uniform doses of cancer cells with various radiosensitivities in each plan were estimated. To account for the spatial fractionation, high dose core number density of the tumor target was defined and calculated. RESULTS: Among 14 plans, the dose-volume histogram indices D5, D10, D50, D90, and D95 (doses covering 5%, 10%, 50%, 90%, and 95% of the target volume) were found within 10% variation. The dose ratio of D10/D90 also showed a moderate consistency (range, 3.9-5.0; mean, 4.4). The equivalent uniform doses were consistent, ranging from 4.3 to 5.5 Gy, mean 4.6 Gy, for radiosensitive cancer cells and from 5.8 to 6.9 Gy, mean 6.2 Gy, for radioresistant cancer cells. The high dose core number density was within 20% among all plans. CONCLUSIONS: GRID collimator-based SFRT delivers a consistent heterogeneity dose distribution and high dose core density across bulky tumor plans. The interplan reproducibility and simplicity of GRID therapy may be useful for certain clinical indications and interinstitutional clinical trial design, and its heterogeneity metrics may help guide multileaf-collimator-based SFRT planning to achieve similar or further optimized dose distributions.


Assuntos
Neoplasias , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Neoplasias/radioterapia , Radiometria/métodos , Dosagem Radioterapêutica
15.
J Vasc Surg Venous Lymphat Disord ; 12(1): 101683, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37708935

RESUMO

OBJECTIVE: We sought to determine whether racial and ethnic disparities existed in inferior vena cava (IVC) filter (IVCF) placement rates among Black and Latino patients for the treatment of acute proximal lower extremity (LE) deep vein thrombosis (DVT) in the United States from 2016 to 2019. METHODS: We performed a retrospective review of National Inpatient Sample data to identify adult patients with a primary discharge diagnosis of acute proximal LE DVT from January 2016 to December 2019, including self-reported patient race and ethnicity. IVCF placement rates were identified using International Classification of Diseases, 10th revision, codes. Weighted multivariable logistic regression was used to compare IVCF use by race and ethnicity. The regression model was adjusted for patient demographics (ie, sex, primary payer, quartile classification of household income), hospital information (ie, region, location, teaching status, bed size), weekend admission, and clinical characteristics (ie, modified Charlson comorbidity index, hypertension, atrial fibrillation, diabetes mellitus type 2, congestive heart failure, dyslipidemia, coronary artery disease, smoking, obesity, alcohol abuse, chronic kidney disease, pulmonary embolism, malignancy, contraindications to anticoagulation, including other major bleeding). RESULTS: Of 134,499 acute proximal LE DVT patients, 18,909 (14.1%) received an IVCF. Of the patients who received an IVCF, 12,733 were White (67.3%), 3563 were Black (18.8%), and 1679 were Latino (8.9%). IVCF placement decreased for all patient groups between 2016 and 2019. After adjusting for the U.S. population distribution, the IVCF placement rates were 11 to 12/100,000 persons for Black patients, 7 to 8/100,000 persons for White patients, and 4 to 5/100,000 persons for Latino patients. The difference in IVCF placement rates was statistically significant between patient groups (Black patients vs White patients, P < .05; Black patients vs Latino patients, P < .05; Latino patients vs White patients, P < .05). CONCLUSIONS: This nationwide study showed that Black patients have higher IVCF placement rates compared with White and Latino patients. Given the known long-term complications and uncertain benefits of IVCFs, coupled with the 2010 U.S. Food and Drug Administration safety warning regarding adverse patient events for these devices, proactive measures should be taken to address this disparity among the Black patient population to promote health equity. Future work should assess whether clinician bias might be perpetuating this disparity.


Assuntos
Embolia Pulmonar , Filtros de Veia Cava , Trombose Venosa , Adulto , Humanos , Estados Unidos , Filtros de Veia Cava/efeitos adversos , Promoção da Saúde , Resultado do Tratamento , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia , Trombose Venosa/complicações , Embolia Pulmonar/etiologia , Estudos Retrospectivos , Veia Cava Inferior
16.
Magn Reson Med ; 91(3): 896-910, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37755319

RESUMO

PURPOSE: To develop a 3D phase modulated UTE adiabatic T1ρ (PM-UTE-AdiabT1ρ ) sequence for whole knee joint mapping on a clinical 3 T scanner. METHODS: This new sequence includes six major features: (1) a magnetization reset module, (2) a train of adiabatic full passage pulses for spin locking, (3) a phase modulation scheme (i.e., RF cycling pair), (4) a fat saturation module, (5) a variable flip angle scheme, and (6) a 3D UTE Cones sequence for data acquisition. A simple exponential fitting was used for T1ρ quantification. Phantom studies were performed to investigate PM-UTE-AdiabT1ρ 's sensitivity to compositional changes and reproducibility as well as its correlation with continuous wave-T1ρ measurement. The PM-UTE-AdiabT1ρ technique was then applied to five ex vivo and five in vivo normal knees to measure T1ρ values of femoral cartilage, meniscus, posterior cruciate ligament, anterior cruciate ligament, patellar tendon, and muscle. RESULTS: The phantom study demonstrated PM-UTE-AdiabT1ρ 's high sensitivity to compositional changes, its high reproducibility, and its strong linear correlation with continuous wave-T1ρ measurement. The ex vivo and in vivo knee studies demonstrated average T1ρ values of 105.6 ± 8.4 and 77.9 ± 3.9 ms for the femoral cartilage, 39.2 ± 5.1 and 30.1 ± 2.2 ms for the meniscus, 51.6 ± 5.3 and 29.2 ± 2.4 ms for the posterior cruciate ligament, 79.0 ± 9.3 and 52.0 ± 3.1 ms for the anterior cruciate ligament, 19.8 ± 4.5 and 17.0 ± 1.8 ms for the patellar tendon, and 91.1 ± 8.8 and 57.6 ± 2.8 ms for the muscle, respectively. CONCLUSION: The 3D PM-UTE-AdiabT1ρ sequence allows volumetric T1ρ assessment for both short and long T2 tissues in the knee joint on a clinical 3 T scanner.


Assuntos
Menisco , Ligamento Patelar , Reprodutibilidade dos Testes , Articulação do Joelho/diagnóstico por imagem , Ligamento Cruzado Anterior/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
18.
NMR Biomed ; 37(2): e5058, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37828713

RESUMO

Muscle degeneration following rotator cuff tendon tearing is characterized by fatty infiltration and fibrosis. While tools exist for the characterization of fat, the ability to noninvasively assess muscle fibrosis is limited. The purpose of this study was to evaluate the capability of quantitative ultrashort echo time T1 (UTE-T1) and UTE magnetization transfer (UTE-MT) mapping with and without fat suppression (FS) for the differentiation of injured and control rotator cuff muscles and for the detection of fibrosis. A rat model of chronic massive rotator cuff tearing (n = 12) was used with tenotomy of the right supraspinatus and infraspinatus tendons and silicone implants to prevent healing. Imaging was performed on a 3-T scanner, and UTE-T1 mapping with and without FS and UTE-MT with and without FS for macromolecular fraction (MMF) mapping was performed. At 20 weeks postinjury, T1 and MMF were measured in the supraspinatus and infraspinatus muscles of the injured and contralateral, internal control sides. Histology was performed and connective tissue fraction (CTF) was measured, defined as the area of collagen-rich extracellular matrix divided by the total muscle area. Paired t-tests and correlation analyses were performed. Significant differences between injured and control sides were found for CTF in the supraspinatus (mean ± SD, 14.5% ± 3.9% vs. 11.3% ± 3.7%, p = 0.01) and infraspinatus (17.0% ± 5.4% vs. 12.5% ± 4.6%, p < 0.01) muscles, as well as for MMF using UTE-MT FS in the supraspinatus (9.7% ± 0.3% vs. 9.5% ± 0.2%, p = 0.04) and infraspinatus (10.9% ± 0.8% vs. 10.1% ± 0.5%, p < 0.01) muscles. No significant differences between sides were evident for T1 without or with FS or for MMF using UTE-MT. Only MMF using UTE-MT FS was significantly correlated with CTF for both supraspinatus (r = 0.46, p = 0.03) and infraspinatus (r = 0.51, p = 0.01) muscles. Fibrosis occurs in rotator cuff muscle degeneration, and the UTE-MT FS technique may be helpful to evaluate the fibrosis component, independent from the fatty infiltration process.


Assuntos
Manguito Rotador , Tendões , Animais , Ratos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Atrofia Muscular , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/patologia
19.
Skeletal Radiol ; 53(2): 209-244, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37566148

RESUMO

OBJECTIVE: Direct magnetic resonance arthrography (dMRA) is often considered the most accurate imaging modality for the evaluation of intra-articular structures, but utilization and performance vary widely without consensus. The purpose of this white paper is to develop consensus recommendations on behalf of the Society of Skeletal Radiology (SSR) based on published literature and expert opinion. MATERIALS AND METHODS: The Standards and Guidelines Committee of the SSR identified guidelines for utilization and performance of dMRA as an important topic for study and invited all SSR members with expertise and interest to volunteer for the white paper panel. This panel was tasked with determining an outline, reviewing the relevant literature, preparing a written document summarizing the issues and controversies, and providing recommendations. RESULTS: Twelve SSR members with expertise in dMRA formed the ad hoc white paper authorship committee. The published literature on dMRA was reviewed and summarized, focusing on clinical indications, technical considerations, safety, imaging protocols, complications, controversies, and gaps in knowledge. Recommendations for the utilization and performance of dMRA in the shoulder, elbow, wrist, hip, knee, and ankle/foot regions were developed in group consensus. CONCLUSION: Although direct MR arthrography has been previously used for a wide variety of clinical indications, the authorship panel recommends more selective application of this minimally invasive procedure. At present, direct MR arthrography remains an important procedure in the armamentarium of the musculoskeletal radiologist and is especially valuable when conventional MRI is indeterminant or results are discrepant with clinical evaluation.


Assuntos
Artrografia , Imageamento por Ressonância Magnética , Humanos , Artrografia/métodos , Radiografia , Imageamento por Ressonância Magnética/métodos , Ombro/diagnóstico por imagem , Punho
20.
Ultrason Imaging ; 46(1): 56-70, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37981826

RESUMO

This study evaluated the repeatability and reproducibility of using high-frequency quantitative ultrasound (QUS) measurement of backscatter coefficient (BSC), grayscale analysis, and gray-level co-occurrence matrix (GLCM) textural analysis, to characterize human rotator cuff muscles. The effects of varying scanner settings across two different operators and two US systems were investigated in a healthy volunteer with normal rotator cuff muscles and a patient with chronic massive rotator cuff injury and substantial muscle degeneration. The results suggest that BSC is a promising method for assessing rotator cuff muscles in both control and pathological subjects, even when operators were free to adjust system settings (depth, level of focus, and time-gain compensation). Measurements were repeatable and reproducible across the different operators and ultrasound imaging platforms. In contrast, grayscale and GLCM analyses were found to be less reliable in this setting, with significant measurement variability. Overall, the repeatability and reproducibility measurements of BSC indicate its potential as a diagnostic tool for rotator cuff muscle evaluation.


Assuntos
Tecido Adiposo , Manguito Rotador , Humanos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Reprodutibilidade dos Testes , Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...